The 878A measures capacitance, resistance (of non-inductive components) and inductance. Components can be measured with selectable test frequencies in series or parallel modes as desired. The 4 1/2 digit main LCD displays values to 19,999, and the secondary 3 digit 1,000 count display reads D or Q. Both models can be used in either auto ranging or manual ranging modes.
 
Features
Selectable test frequencies 120Hz, 1KHz
Simultaneously displays measured component value and Q or Dissipation Factor (D)
Display hold
Relative mode
Tolerance mode
RS 232 Interface (cable and software required)
 
General Specification
Items:
Model 879
Model 878A
Parameters Measured
L/C/R/D/Q/Θ
L/C/R/D/Q
Measuring Circuit Mode
Inductance (L)
–Defaults to series mode
Capacitance/ Resistance (C/R)
-Defaults to parallel mode
Displays
L/C/R: Maximum display 19999
D/Q: Maximum display 999 (Auto Range).
Ranging Mode
Auto & Manual
Measuring Terminals
3 terminals with sockets
Test Frequency
Accuracy:
±0.1 %
100Hz=100 Hz
120Hz= 120 Hz
1KHz =1010 Hz
10KHz= 9.6 KHz
120Hz= 120 Hz
1KHz =1010 Hz
Backlit display
Included
Excluded
Tolerance mode
1%, 5%, 10%, 20%
1%, 5%, 10%
Test Signal Level
0.6Vrms approx.
Measuring Rate
1 time/second, nominal
Response time
Approx. 1 second/ DUT (device under test)(@ manual range)
Auto Power-Off
5 minutes approx. without operation
Temperature Coefficient
0.15 x (Specified Accuracy) / ℃(0-18℃ or 28-40℃)
Operation Temperature
0℃ to 40℃; 0-70% R.H.
Storage Temperature
-20℃ to +50℃; 0-80% R.H.
Low Battery Indication
Approx. 6.8V
Power Consumption
Approx. 40mA for operation/ 0.08mA after Auto Power-off.
Power Requirements
1) DC 9V Battery
2) Ext. DC Adaptor: DC 12Vmin –15Vmax. (Load 50mA Min.)
Protective Fuse
0.1A/250V Fuse (input protective)
Standard Accessories
Test alligator clips (pair)
DC 9V Battery.
User manual
Dimensions (L/W/H)
7.2/ 3.4/ 1.6" (184/ 87/ 41 mm)
Weight
11.6oz (330 grams)
 
 
 
Electrical Specification
Accuracy is expressed as: ± (% of reading + no. of least significant digits) at 23℃±5℃and <75% R.H.
Model 879:
o Resistance (Parallel mode)
Test Frequency: 100 / 120 Hz
Range
Maximum Display
Accuracy
Specified Note
@100 Hz
@120Hz
10MW
9.999MW
2.0%+8 *3
2.0%+8 *3
After open cal.
2000KW
1999.9KW
0.5%+5
0.5%+5
After open cal.
200KW
199.99KW
0.5%+3
0.5%+3
-
20KW
19.999KW
0.5%+3
0.5%+3
-
2000W
1999.9W
0.5%+3
0.5%+3
-
200W
199.99W
0.8%+5
0.8%+5
After short cal.
20W
19.999W
1.2%+40
1.2%+40
After short cal.
Test Frequency: 1K / 10K Hz
Range
Maximum Display
Accuracy
Specified Note
@1K Hz
@10KHz
10 MW
9.999MW
2.0%+8 * 3
3.5%+10 * 3
After open cal.
2000 KW
1999.9KW
0.5%+5
2.0%+10
After open cal.
200 KW
199.99KW
0.5%+3
1.5%+5
-
20 KW
19.999KW
0.5%+3
1.5%+5
-
2000 W
1999.9 W
0.5%+3
1.5%+5
-
200 W
199.99 W
0.8%+5
2.0%+10
After short cal.
20 W
19.999 W
1.2%+40
2.5%+200
After short cal.
Notes:
1.      This specification is based on the measurement performed at the test socket.
2.      DUT (Device Under Test) & Test leads be properly shielded to GUARD if necessary.
3.      This specification is based on battery operation.
o Capacitance (Parallel mode) Test Frequency: 100 / 120 Hz
Range
Maximum Display
Accuracy
Spec. Note
Capacitance
DF
10mF
19.99mF *5
3.0%+5
(DF<0.1)
10%+100/Cx+5 (DF<0.1)
After short cal.
1000μF
1999.9μF*6
1.0%+5
(DF<0.1)
2%+100/Cx+5 (DF<0.1)
After short cal.
200μF
199.99μF
0.7%+3
DF<0.5
0.7%+100/Cx+5 (DF<0.5)
-
20μF
19.999μF
0.7%+3
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
-
2000nF
1999.9nF
0.7%+3
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
-
200nF
199.99nF
0.7%+5
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
After open cal.
20nF
19.999nF
1.0%+5
(DF<0.1)
2%+100/Cx+ (DF<0.1)
After open cal.
Test Frequency: 1 KHz
Range
Maximum Display
Accuracy
Spec. Note
Capacitance
DF
1mF
1.999mF *5
3.0%+5
(DF<0.1)
10%+100/Cx+5 (DF<0.1)
After short cal.
200μF
199.99μF
1.0%+5
(DF<0.1)
2.0%+100/Cx+5 (DF<0.1)
After short cal.
20μF
19.999μF
0.7%+3
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
-
2000nF
1999.9nF
0.7%+3
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
-
200nF
199.99nF
0.7%+3
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
-
20nF
19.999nF
0.7%+5
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
After open cal.
2000pF
1999.9pF
1.0%+5
(DF<0.1)
2.0%+100/Cx+5 (DF<0.1)
After open cal.
Test Frequency: 10 KHz
Range
Maximum Display
Accuracy
Spec. Note
Capacitance
DF
50μF
50.0μF
3.0%+8
(DF<0.1)
12%+100/Cx+10 (DF<0.1)
After short cal.
20μF
19.999μF
3.0%+6
(DF<0.2)
5.0%+100/Cx+8 (DF<0.2)
After short cal.
2000nF
1999.9nF
1.5%+5
(DF<0.5)
1.5%+100/Cx+6 (DF<0.5)
-
200nF
199.99nF
1.5%+5
(DF<0.5)
1.5%+100/Cx+6 (DF<0.5)
-
20nF
19.999nF
1.5%+5
(DF<0.5)
1.5%+100/Cx+6 (DF<0.5)
-
2000pF
1999.9pF
2.0%+6
(DF<0.5)
3.0%+100/Cx+6 (DF<0.5)
After open cal.
200pF
199.99pF
3.0%+8
(DF<0.1)
5.0%+100/Cx+8 (DF<0.1)
After open cal.
Notes:
1.    Q Value is the reciprocal of DF.
2.    This specification is based on the measurement performed at the test socket.
3.    DUT & Test leads should be properly shielded to GUARD if necessary.
4.    Cx=Counts of displayed C value, e.g. C=88.88μF then Cx=8888.
5.    This reading can be extended to 1999 MAX display with accuracy not specified.
6.    This reading can be extended to 19999 MAX display with accuracy not specified.
oInductance(Series mode)
Test Frequency: 100 / 120Hz
Range
Maximum
Display
Accuracy (DF<0.5)
Spec. Note
Inductance
DF
1000H
999.9H
1.0%+(Lx
/10000) %+5
2%+100/Lx+5
After open cal.
200H
199.99H
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
20H
19.999H
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
2000m
1999.9mH
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
200mH
199.99mH
1.0%+(Lx
/10000)%+5
3%+100/Lx+5
After short cal.
20mH
19.999mH
2.0%+(Lx
/10000)%+5
10%+100/Lx+5
After short cal.
Test Frequency: 1 KHz
Range
Maximum Display
Accuracy (DF<0.5)
Spec. Note
Inductance
DF
100H
99.99H
1.0%+(Lx
/10000) %+5
2.0%+100/Lx+5
After open cal.
20H
19.999H
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
2000mH
1999.9mH
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
200mH
199.99mH
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
20mH
19.999mH
1.0%+(Lx
/10000)%+5
3.0%+100/Lx+5
After short cal.
2000mH
1999.9mH
2.0%+
(Lx/10000)%+5
10%+100/Lx+5
After short cal.
Test Frequency: 10 KHz
Range
Maximum Display
Accuracy (DF<0.5)
Spec. Note
Inductance
DF
1000mH
999.9mH
2.0%+(Lx
/10000)%+ 8
2.0%+100/Lx+10
-
200mH
199.99mH
1.5%+(Lx
/10000)%+8
2.0%+100/Lx+10
-
20mH
19.999mH
1.5%+(Lx /10000)%+10
3.0 %+100/Lx+15
-
2000mH
1999.9mH
2.0%+(Lx /10000)%+10
8.0 %+100/Lx+20
After short cal.
Notes:
1.    1.Q Value is the reciprocal of DF.
2.    This specification is based on the measurement performed at the test socket.
3.    DUT & Test leads shall be properly shielded to GUARD if necessary.
4.    Lx=counts of displayed L value, e.g. L=88.88H, then Lx=8888.
 
Model 878A:
oResistance (parallel mode)
Test Frequency: 120Hz / 1KHz
Range
Maximum Display
Accuracy
Specified Note
@120 Hz
@1KHz
10MW
9.999MW
2.0%+8 *3
2.0%+8 *3
After open cal.
2000KW
1999.9KW
0.5%+5
0.5%+5
After open cal.
200KW
199.99KW
0.5%+3
0.5%+3
-
20KW
19.999KW
0.5%+3
0.5%+3
-
2000W
1999.9W
0.5%+3
0.5%+3
-
200W
199.99W
0.8%+5
0.8%+5
After short cal.
20W
19.999W
1.2%+40
1.2%+40
After short cal.
Notes:
1.      This specification is based on the measurement performed at the test socket.
2.      DUT (Device Under Test) & Test leads be properly shielded to GUARD if necessary.
3.      This specification is based on battery operation.
o Capacitance (parallel mode) Test Frequency: 120 Hz
Range
Maximum Display
Accuracy
Spec. Note
Capacitance
DF
10mF
19.99mF *5
3.0%+5
(DF<0.1)
10%+100/Cx+5 (DF<0.1)
After short cal.
1000μF
1999.9μF*6
1.0%+5
(DF<0.1)
2%+100/Cx+5 (DF<0.1)
After short cal.
200μF
199.99μF
0.7%+3
DF<0.5
0.7%+100/Cx+5 (DF<0.5)
-
20μF
19.999μF
0.7%+3
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
-
2000nF
1999.9nF
0.7%+3
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
-
200nF
199.99nF
0.7%+5
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
After open cal.
20nF
19.999nF
1.0%+5
(DF<0.1)
2%+100/Cx+ (DF<0.1)
After open cal.
Test Frequency: 1 KHz
Range
Maximum Display
Accuracy
Spec. Note
Capacitance
DF
1mF
1.999mF *5
3.0%+5
(DF<0.1)
10%+100/Cx+5 (DF<0.1)
After short cal.
200μF
199.99μF
1.0%+5
(DF<0.1)
2.0%+100/Cx+5 (DF<0.1)
After short cal.
20μF
19.999μF
0.7%+3
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
-
2000nF
1999.9nF
0.7%+3
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
-
200nF
199.99nF
0.7%+3
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
-
20nF
19.999nF
0.7%+5
(DF<0.5)
0.7%+100/Cx+5 (DF<0.5)
After open cal.
2000pF
1999.9pF
1.0%+5
(DF<0.1)
2.0%+100/Cx+5 (DF<0.1)
After open cal.
Notes:
1.    Q Value is the reciprocal of DF.
2.    This specification is based on the measurement performed at the test socket.
3.    DUT & Test leads should be properly shielded to GUARD if necessary.
4.    Cx=Counts of displayed C value, e.g. C=88.88μF then Cx=8888.
5.    This reading can be extended to 1999 MAX display with accuracy not specified.
6.    This reading can be extended to 19999 MAX display with accuracy not specified.
 
oInductance (Series mode)
Test Frequency: 120Hz
Range
Maximum
Display
Accuracy (DF<0.5)
Spec. Note
Inductance
DF
1000H
999.9H
1.0%+(Lx
/10000) %+5
2%+100/Lx+5
After open cal.
200H
199.99H
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
20H
19.999H
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
2000m
1999.9mH
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
200mH
199.99mH
1.0%+(Lx
/10000)%+5
3%+100/Lx+5
After short cal.
20mH
19.999mH
2.0%+(Lx
/10000)%+5
10%+100/Lx+5
After short cal.
Test Frequency: 1 KHz
Range
Maximum Display
Accuracy (DF<0.5)
Spec. Note
Inductance
DF
100H
99.99H
1.0%+(Lx
/10000) %+5
2.0%+100/Lx+5
After open cal.
20H
19.999H
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
2000mH
1999.9mH
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
200mH
199.99mH
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
20mH
19.999mH
1.0%+(Lx
/10000)%+5
3.0%+100/Lx+5
After short cal.
2000mH
1999.9mH
2.0%+
(Lx/10000)%+5
10%+100/Lx+5
After short cal.
 
購買提示  

BK878A通用LCR測試器

購買提示

1.閣下有任何產(chǎn)品問題請致電400-663-9117.
2.中儀將提供北京、上海、深圳、南京、重慶送貨上門服務(wù).
3.我們提供BK878A通用LCR測試器計量送檢,在簽收前請詳細(xì)核查資料信息.
4.TY10BK878A通用LCR測試器價格根據(jù)配置和貨期不同而不同,具體以合同為準(zhǔn).
5.我們?yōu)殚w下提供保修TY10BK878A通用LCR測試器售后維修服務(wù),提供后期技術(shù)支持.
6.閣下對TY10BK878A通用LCR測試器使用方法等有需求時,將為閣下找到BK878A通用LCR測試器說明書.
最近瀏覽

SEFRAMBK878A通用LCR測試器

代理商廠商品牌售后維修區(qū)域:北京-上海-浙江-廣東-河南-杭州-鄭州-廣州-深圳-佛山-惠州-廈門-汕頭-臺灣-香港-天津-西安-寶雞-杭州-溫州-常州-無錫-蘇州-南京-鎮(zhèn)江-揚(yáng)州-南通-合肥-徐州-常熟-石家莊-太原-呼和浩特-沈陽-長春-哈爾濱-南京-合肥-福州-南昌-濟(jì)南-鄭州-武漢-長沙-廣州-南寧-???成都-貴陽-昆明-拉薩-西安-蘭州-西寧-銀川-烏魯木齊-杭州-沈陽-長春-哈爾濱-濟(jì)南-武漢-廣州-南寧-成都-西安-大連-寧波-廈門-青島-深圳-杭州-淮安-連云港-昆山-嘉興-湖州-秦皇島-邯鄲-邢臺-保定-張家口-承德-廊坊-呼和浩特-包頭-鞍山-大慶-錦州-鐵嶺-盤錦-湛江-蕭山-遼寧-淄博-寧夏-綿陽-云南-朝陽-陜西-青海-北海-唐山-吉林-蘇州-昆山-無錫-鎮(zhèn)江-常州-連云港-淮安-淮陰-鹽城-揚(yáng)州-徐州-宜興-江陰-南通-揚(yáng)州-上海-滁州-內(nèi)蒙古-新疆有銷售.北京亦莊開發(fā)區(qū),天津濱海開發(fā)區(qū),秦皇島經(jīng)濟(jì)開發(fā)區(qū),太原經(jīng)濟(jì)開發(fā)區(qū),呼和浩特經(jīng)濟(jì)開發(fā)區(qū),沈陽經(jīng)濟(jì)開發(fā)區(qū),營口經(jīng)濟(jì)開發(fā)區(qū),大連經(jīng)濟(jì)開發(fā)區(qū),長春經(jīng)濟(jì)開發(fā)區(qū),哈爾濱經(jīng)濟(jì)開發(fā)區(qū),虹橋經(jīng)濟(jì)開發(fā)區(qū),漕河涇開發(fā)區(qū),連云港開發(fā)區(qū),南通開發(fā)區(qū),昆山開發(fā)區(qū),南京開發(fā)區(qū),杭州開發(fā)區(qū),蕭山開發(fā)區(qū),溫州開發(fā)區(qū),寧波開發(fā)區(qū),蕪湖開發(fā)區(qū),合肥開發(fā)區(qū),福州開發(fā)區(qū),福清融僑開發(fā)區(qū),東山開發(fā)區(qū),南昌開發(fā)區(qū),威海開發(fā)區(qū),煙臺開發(fā)區(qū),青島開發(fā)區(qū),鄭州開發(fā)區(qū),武漢開發(fā)區(qū),長沙開發(fā)區(qū),蘿崗區(qū)開發(fā)區(qū),廣州南沙開發(fā)區(qū),惠州大亞灣開發(fā)區(qū),湛江開發(fā)區(qū),南寧開發(fā)區(qū),重慶開發(fā)區(qū),成都開發(fā)區(qū),貴陽開發(fā)區(qū),昆明開發(fā)區(qū),拉薩開發(fā)區(qū),西安開發(fā)區(qū),蘭州開發(fā)區(qū),西寧開發(fā)區(qū),銀川開發(fā)區(qū),烏魯木齊開發(fā)區(qū),石河子開發(fā)區(qū),金橋出口加工區(qū),蘇州工業(yè)園,寧波大榭開發(fā)區(qū),廈門海滄投資區(qū),海南洋浦開發(fā)區(qū)。

按字母分類: A| B| C| D| E| F| G| H| I| J| K| L| M| N| O| P| Q| R| S| T| U| V| W| X| Y| Z| 熱門一| 熱門二| 熱門三| 熱門四| 熱門五|


中儀主頁聯(lián)系中儀了解中儀版權(quán)聲明友情鏈接站點地圖廣告服務(wù)
CopyRight 2003年創(chuàng)立  版權(quán)所有  MRO工業(yè)品就是要儀器網(wǎng)
(5)
產(chǎn)品對比產(chǎn)品對比 隱藏對比框
對不起,您還沒有選擇產(chǎn)品
開始對比清 空